This corrosion increases the resistance of the connection and generates a lot of heat due to the high current of 6 to 8 amps. The Salinity button C on the sanitizer user interface keypad can be used to determine salinity. Reviewed in the United States on October 9, 2013. The center prong is the most common point of failure. eschewing the conventional role in traditional architectural hierarchies, this project acts as a catalyst to an overcrowded favela by bringing in social infrastructure and a connection between top . See also, Section 6.4, Flow/Temp/Salinity Sensor Cleaning, Step 4 of the owner's manual. Need to, Your zip code will help us to provide you with the most up-to-date delivery information. Disconnect the flow salinity temp sensor from the front board. A 121 error can occur for a number of different reasons: dirty cell, damaged cell, bad cell cable, low salt level, cell wearing out due to age, or damaged power supply. A great system, easy to install. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. Jandy - Power Center Transformer for AquaLink RS and AquaPure - Leslie's It displays the salt level in PPM on the display, and you can set the production rate (0-100%) on the LCD display, or you can integrate the system with a Jandy controller as I did. Zodiac APUREM AquaPure Foundation Power Center Pack Replacement for Used On Jandy AquaPure and ClorMatic Metal Control Box Systems. Full content visible, double tap to read brief content. This warranty applies only to products installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed, where such state or local requirements exists. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. We selected and analyzed the cases involving AEDs. The AquaPure cells can be controlled by the AquaPure user interface inside the control/power center or by the Aqualink automation systems. Changes to Aquapure settings made on Aqualink will not show on the Aquapure and the chlorine% will be 0. Salt Water Pool Generator Control Center Model# APUREM Retail is $1000 The aquapure power center is an electrical panel that is installed at the equipment pad. Looks like your current store isn't near your delivery area. From the Jandy controller, you can see the salt PPM, and you get a An excellent system. contain additives. Told me from the serial number on unit it should have been included. Drop in the Best When You Replace the Rest. How does Aqualink RS Manage Solar and Gas Heating, Jandy IAqualink WiFi module with PDA Remote, iAqualink freeze protection - two specific questions, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Check for dirt or corrosion around DC cord contacts at cell. Apple is not a participant or sponsor of this promotion. The mineral purifier cartridge may have ruptured. Available in 7 or 14-blade configurations. 2023 Zodiac Pool Systems LLC - All rights reserved. When replacing the cell, it's important to replace the power cord so that the connections are clean and the resistance is minimized.[3]. PDF WARNING - INYOPools.com In addition, the AquaPure threads are proprietary and Jandy does not offer replacement proprietary unions (the "male" piece). good documentation. Will there be any harm if someone swallows salt water in a salt chlorinated pool? See Section 4.5 of the owner's manual. There was a problem adding this item to Cart. Add salt as described in Section 4.7 of the owner's manual. That can be from low salt, low water temperature, a bad power cord, cell plates corroded or loose power pins. What is polarity inversion on a salt water chlorinator? You can check the calibration by doing the following below procedure. The AquaPure does not have a flow switch, it has a flow sensor, which is a heated probe and and unheated probe and it works on the same principle as "wind chill".[1]. Prime pump if necessary. It's usually cheaper to buy the Aquapure 1400 cell kit that comes with the cell, trisensor and power cord vs. buying the parts separately. VERY GOOD PRODUCT, indeed, easy to install. You will also find the cell sold alone at a lower price then the kit and it is tempting to buy only the cell. Note that the center prong is on the cell where the power cord connects to the cell. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. We made the decision to go to a salt water pool system. Jandy AquaPure Power Center APUREM Controller | PoolSupply4Less Porto Seguro Cultural Center / Yuri Vital | ArchDaily While the salt water chlorinator prevents the user from needing to add chlorine to the pool on a regular basis, some maintenance, in regards to water balancing, will still need to be accomplished. See wiring diagram in Figures 2a, 2b, and 2c of the owner's manual. Had to down load from another site. 4.5 out of 5 stars 354 $ 1,098. For all your hard to find pool and spa parts, including above ground spa parts, , Copyright 2023 Pool and Spa Parts Depot. The AquaPure has a 3 hour polarity cycle time (3 hours one polarity, 3 hours reverse polarity). Winterize your pool. JANDY AQUAPURE PLASTIC CONTROL CENTER, MODELS 700 & 1400 JANDY AQUAPURE | CONTROL BOX, PURE1400 | R0403000 Categories POOL PARTS SPA PARTS CHEMICAL FEEDER CLEANERS FILTERS FILTER ELEMENTS FILTER VALVES FITTINGS & UNIONS HEATERS LIGHTS PILLOW PLEATCO PLUMBING VALVES PUMPS SKIMMERS SPA AIR BLOWERS SPA FITTINGS SPA PACK CONTROL COMPONENTS PLASTIC CONTROL CENTER, MODELS 700 & 1400, PARTS - BIG DIPPER, ECLIPSE, TOTAL ECLIPSE, COMPLETE HIGHCAPACITY BROMINE & CHLORINE FEEDERS, KREEPY E-Z VAC & KREEPY KADET ACCESSORIES, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, AMERICAN PRODUCTS 5 & 8 POSITION TOP MOUNT, SPA DRAIN & ON/OFF VALVES FOR GARDEN HOSE, STANDARD HEATER UNION COMPONENTS - 1", 200 SERIES TYPHOON JETS - SCALLOPED, 2" FACE, 300 SERIES TYPHOON JETS - SCALLOPED, 3" FACE, 400 SERIES TYPHOON JETS - SCALLOPED, 4" FACE, 500 SERIES TYPHOON JETS - SCALLOPED, 5" FACE, RETRO FITTING LEN GORDON & OTHER CONTROLS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, 200 SERIES TYPHOON JETS - SCALLOPED, 4" FACE, JANDY AQUAPURE | CONTROL BOX, PURE700 | R0402900, JANDY AQUAPURE | UNION NUT, 2" BLACK | R0412500, JANDY AQUAPURE | SALINITY METER | R0475300, JANDY AQUAPURE Ei | TS CONTROL PCB ASSY | R0512300, JANDY AQUAPURE | SPOOL PIECE, 2" BLACK UNIONS W/2803-009 | R0412800, POLARIS OZONATORS | 110/220V FOR UP TO 40,000 GALLONS | PZVII-2 | Discontinued, PENTAIR | HC-3330 HOUSING W/ 2098-0 | R172437, Pool and Spa Parts Depot | Swimming Pool Supplies. This method would require the purchase of 4 unions. 624537. Jandy AquaPure ClorMatic System Parts Metal Controller When I check the water temperature on my Aqualink Control Center by quickly pressing the Pool Temp Boost button, it shows 85 degrees which I believe is correct. JavaScript is disabled. This applies to the Jandy AquaPure and the Nature2 FusionSoft as they are sister products. Get 1 point for every $1 spent. A member found that the new part fit perfectly with the same mounting holes. Free Shipping and more for Pool Perks members. We had to replace the filter and pump body! The PureLink Power Centers combine all the features of the AquaLink Power Centers and AquaPure water purification electronics in one box. PDF Jandy Aqua Pure In preparation, I had upgraded our controller to the latest release of hardware and software, so I was familiar with most of the circuitry involved. ORP / External Control Interface 2. Must be picked up in our Moorpark, Ca location to qualify for the Jandy limited warranty. Then the Aquapure system will be connected to your Aqualink system. If its 02110A10 or 01220A15, you use program A, otherwise you use program B on the in-line module on the trisensor cord. When I check the water temperature on my Aqualink Control Center by quickly pressing the Pool Temp Boost button, it shows 85 degrees which I believe is correct. Test the salt level with a K-1766 Taylor Salt Test. You are using an out of date browser. Avoid using salt with anti-caking agents (sodium ferrocyanide, also known as YPS or yellow prussiate of soda) that could cause some discoloration of fittings and surface finishes in pool. The remaining bromide will not harm the users, pool equipment or the pool. Please obtain a google maps API key and put it in Site Preferences! Regular Price: $212.61. The systems are comprised of the following components: Arrived sooner than promised. Refer to Maintenance Procedure for acid wash cleaning. veggiebenz; Aug 8, 2022; Salt Water Chlorine Generators (SWG) Replies 2 . Wichita Falls, TX. Remove cell for inspection. Works like a champ. Do Not use Rock salt (insoluble impurities mixed with the rock salt can shorten the life of the unit). inground with iAqualink remote control. The remaining bromide in the pool will produce a white emulsion (chemical reaction). App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. The only hiccup we get, is an occasional communication error. If the readings are correct then the board is O.K. Currently, Jandy has part R0481400 which is the round transformer. Free shipping for many products! PDF WARNING - bestbuypoolsupply.com We could have gotten by with the PLC700 but this We made the decision to go to a salt water pool system. Would buy again from them. We paired it with the APUREM. Field switchable to power all PureLink, ClorMatic and Nature2 Fusion Soft cell kits, LCD monitoring of chlorine production, cell modes, salinity, temperature, water flow and diagnostics. Jandy no longer supports parts for their older systems. Increase the system operating time per day. Check for correct operation of the pump. If the actual salinity is above 4.0 gpl (4,000 ppm), the pool needs to be diluted to get the level below 4.0 gpl. It is the box in which the bezel, printed circuit board, service control panel and relays of the system control are installed and to which the pool equipment is connected. $200 later guy said unit was shipped without a translatetor card???? It should read 75 F or 24 C. Next, press and hold the board H-Temp test button, and at the same time press the Salinity key (C) together with the Chlorine Production Rate arrow down key (A) on the front cover of the unit. Make sure that the salt is very well mixed by brushing thoroughly at least 5 times. Shop Online or at any of our 900+ retail stores! Low salt concentration below 2.0 gpl will cause premature cell failure. If chlorine output at the lowest setting consistently provides for excessive chlorine levels, decrease daily pump operation time as much as necessary. Work the first time without any issue or abnormal event. See Section 6 of the owner's manual, User Maintenance Instructions. In the event no such state or local requirement exists, the installer and maintainer must be a professional with sufficient experience in pool equipment installation and maintenance.". Being relatively adept, I chose to install this myself. You can buy this product once, or subscribe to have this product delivered to you as frequently as you wish. If not, contact a pool professional. Brush the pool bottom and allow water to circulate for 24 hours to dissolve salt completely and mix evenly >PoolAndSpaPartsDepot.com is Open for Business! I've had a Jandy Aquapure 1400 since I opened the pool 4 years ago, and it's in the process of dying. www.poolandspapartsdepot.com Most cases of corrosion can be better explained by an incorrect water chemistry as opposed to the presence of salt. Reviewed in the United States on September 23, 2016, Reviewed in the United States on February 1, 2015, Reviewed in the United States on April 28, 2014. Please use a different way to share. 21. AquaPure Salt Water Pool System - Jandy Zodiac Brand Item Number R0467600. The Power Center comes configured for the 1400 cell and the JL1 jumper must be cut if using the 700 cell. Free shipping for many products! If there's a little adapter card between the old sensor cord and the circuit board, remove the adapter card. Ensure that the flow/temp/salinity sensor is installed according to Section 3, Figure 11 of the owner's manual. Learn more. ), PURE1400 - 1.25 lb./24 Hr. (567 gm/24 Hr.). New, not old stock, in sealed box. See Section 6.3 of the owner's manual Electrolytic Cell Cleaning. No warranty when purchased online. It is usually located underneath your Aqualink cabinet. Even the High Voltage side wires were color coded identically. The LCD display on the user interface offers monitoring of chlorine production, cell modes, salinity level, temperature, water flow and diagnostics. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. Search in reviews, Q&A. The 700 cell has half the number of plates as the 1400 cell. One method is an additional PVC union after each end of the cell. Test salinity by pressing the Test Salinity button. For a better experience, please enable JavaScript in your browser before proceeding. NOTE: To clean the deposit (scale) on the electrolytic cell plates, see Section 6.3 of the owner's manual.